MF63
Steel grade: S355J2
Steel thickness: 0.47“ (12 mm)
Standard lengths: 26.25 ft, 38.7 ft (8 m, 11.8 m)
Weight M35: 3.2 lbs/ft (4.76 kg/m)
Weight F28: 7.19 lbs/ft (10.7 kg/m)
Max. tensile strength: 14.57 kips/in (2,552 kN/m), (FEM)
Data sheet (PDF)
DWG M35
DWG F28
Request this connector
Remember this connector
For Ball + Socket sheet piles
image_MF63 (1)_1765446989.png

MF75
Steel grade: S355J2
Steel thickness: 0.47“ (12 mm)
Standard lengths: 26.25 ft, 38.7 ft (8 m, 11.8 m)
Weight M35: 3.2 lbs/ft (4.76 kg/m)
Weight F40: 9.595 lbs/ft (14.28 kg/m)
Max. tensile strength: 19.52 kips/in (3,419 kN/m)
Data sheet (PDF)
Test report (PDF)
DWG M35
DWG F40
Request this connector
Remember this connector
For Ball + Socket sheet piles
image_MF75 (1)_1765444744.png

MF100
Steel grade: S355J2
Steel thickness: 0.47" (12 mm)
Standard lengths: 26.25 ft, 38.7 ft (8 m, 11.8 m)
Weight M60: 4.64 lbs/ft (6.9 kg/m)
Weight F40: 9.595 lbs/ft (14.28 kg/m)
Max. tensile strength: 19.52 kips/in (3,419 kN/m)
Data sheet (PDF)
Test report (PDF)
DWG M60
DWG F40
Request this connector
Remember this connector
For Ball + Socket sheet piles
image_MF100(1)_1765617858.png

MF130
Steel grade: S355J2
Steel thickness: 0.47" (12 mm)
Standard lengths: 26.25 ft, 38.7 ft (8 m, 11.8 m)
Weight M90: 6.56 lbs/ft (9.76 kg/m)
Weight F40: 9.595 lbs/ft (14.28 kg/m)
Max. tensile strength: 18.27 kips/in (3,419 kN/m)
Data sheet (PDF)
Test report (PDF)
DWG M90
DWG F40
Request this connector
Remember this connector
For Ball + Socket sheet piles
image_MF130(1)_1765438805.png

MF180b
Steel grade: S355J2
Steel thickness: 0.47“ (12 mm)
Standard lengths: 26.25 ft, 38.7 ft (8 m, 11.8 m)
Weight M90: 6.56 lbs/ft (9.76 kg/m)
Weight F90: 12.38 lbs/ft (18.42 kg/m)
Max. tensile strength: 12.15 kips/in (2,128 kN/m)
Data sheet (PDF)
Test report (PDF)
DWG M90
DWG F90
Request this connector
Remember this connector
For Ball + Socket sheet piles
image_MF180(1)_1765435409.png

MF230
Steel grade: S355J2
Steel thickness: 0.47“ (12 mm)
Standard lengths: 26.2 ft, 38.7 ft (8 m, 11.8 m)
Weight M140: 9.92 lbs/ft (14.77 kg/m)
Weight F90: 12.38 lbs/ft (18.42 kg/m)
Max. tensile strength: 12.151 ch kips/in (2,128 kN/m)
Data sheet (PDF)
Test report (PDF)
DWG M140
DWG F90
Request this connector
Remember this connector